Connection to the flue pipe, Smoke valve (optional), Flue pipe – MCZ Hydrotherm 70 User Manual

Page 11

background image

INSTALLATION AND USE MANUAL

Chapter 2

page

11

Theoretical notions for installation

Technical service – MCZ GROUP S.p.A. all rights reserved - Reproduction prohibited

30°

2.4. CONNECTION TO THE FLUE PIPE

The connection to the flue pipe is a very important element. The

connection must be made with a great deal of care; in the event of

erroneous or anomalous construction, it is extremely difficult to remedy

without damaging the hood liner. In addition, the connection is made in

a part of the stove where temperatures are very high, and for this

reason it is important to use materials that are capable of resisting heat

and also the acidity of the fumes produced by combustion.
Before beginning work, please note the following:

 The connecting pipe must have a maximum slope of 45

degrees. This is to avoid excessive deposit of condensation

produced in the initial phases of lighting the fireplace stove,

and/or the excessive accumulation of creosote. It also keeps

the release of smoke from being slowed down.

The unions must be made of metal and suitable for the

specific operating conditions of the product and marked

EC (EN1856-2). The use of flexible and extending metal

pipes is not permitted.

 The components making up the connecting pipe must be

perfectly sealed.

 The joint to the flue pipe must not be too long (to avoid

obstructions), nor too short (to avoid smoke leakage).

If metal connecting pipes are used, they must be

insulated with suitable material such as ceramic fibre

matting, to avoid deterioration of the masonry and of

the decorative hood liner.

IMPORTANT!
Any increase in the section of the connecting pipe

must start immediately above the hood of the

fireplace and not along the flue pipe section.

2.4.1.

Smoke valve (optional)

In case of excessive draught in the flue chimney, combustion may

become unbalanced and consequently less efficient. In this case, in

order to improve combustion efficiency, it is advisable to install the

smoke valve (optional) directly at the output of the fireplace stove. If

you wish to position the control knob (B in the figure) at the front of

the product, it is necessary to place a 25 cm extension of the smoke

duct between the fireplace stove and the valve.

2.5. FLUE PIPE

The flue pipe is a fundamental element in discharging smoke and

therefore must have the following requisites:

It must be waterproof and thermally insulated.

It must be made with heat resistant materials, resistant to

combustion products and any condensation.

have a vertical arrangement with deviations from the axis of

no more than 45° and without kinks.

must be suitable for the specific operating conditions of the

product and marked EC (EN1856-1, EN1443).

Example of fireplace stove connection in

flue chimney

Illustration of a correctly constructed

chimney flue with a chamber and sealed

door (A) for solid combustion product

collection and discharge at the foot of the

external ascending segment.

Smoke

connection

Flue pipe

Hood grille

45° max

Smoke valve

A

B

Ceramic fibre

insulation