beautypg.com

Maintenance of kit vf (if installed) – MCZ AirSystem 70 DX User Manual

Page 36

background image

Chapter 6

INSTALLATION AND USE MANUAL

page

36

Maintenance and cleaning

Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited

Flue pipe with poor performance which does not allow fireplace

stove to reach high yield that results in adequate temperature of

the refractory material.

Never clean the refractory material with a damp cloth

or anything else, as it may be stained.
Use a dry paintbrush if necessary to remove heavy

soot build-up.

If the Alutec does not whiten, it is not to be

considered as a defect in light of the warnings and

instructions above.

6.1.4. Lubrication and routine maintenance of the

extensible guides

All of the doors of the fireplace stoves are mounted on extensible ball-

bearing guides that ensure a robust, sturdy system that provides silent

movement.
Prolonged use and the heat of the fireplace stove gradually depletes

the lubricant in the guides. This will cause them to become less efficient

and noisier.
If necessary, periodically grease both runners as follows:

• Completely raise the door of the fire box so as to see the lower

parts (tracks) of the two guides.

• Using the provided grease gun, apply two drops of grease,

about 5 mm in diameter, at the highest visible point of the

runners. Do not exceed the recommended amount!

• Perform this operation on both guides. Keep in mind that the

total amount of grease to be used is about 0.5 ml (see

graduated scale on grease gun).

After lubrication:

• Put the glue gun back and conserve it
• Lower and raise the door completely at least 6 or 7 times so

that the grease is spread onto all of the other components of

the guides to complete lubrication. You should notice a

substantial improvement in ease of movement and noise

reduction.

It is advisable to carry out this operation at the end of

the season of use, or whenever the runners become

too noisy.
Do not use other types of grease. If the grease gun

runs out, request an MCZ original replacement.

6.1.5. Maintenance of kit VF (if installed)

The maintenance of all electrical parts (fan, control

unit, etc.) must only be carried out with no electrical

power supplied and with the unit unplugged.


Figure 31 – Points to be greased with provided

grease gun