Chapter 3 installation and use manual, Airsystem t60 technical specifications, Flue pipe – MCZ AirSystem 70 DX User Manual
Page 12: Airsystem f60 technical specifications

Chapter 3
INSTALLATION AND USE MANUAL
page
12
Dimensions and technical specifications
Technical service – MCZ S.p.A. all rights reserved - Reproduction prohibited
Airsystem T60
Technical specifications
Fuel type
Wood - Logs
Hourly consumption
3.1 kg/h – 2.2 kg/h
Nominal thermal power
kW 10 Kcal 8600
Efficiency 74.8%
Heatable volume *
215/40 - 246/35 - 287/30
Minimum draught
12 Pa / 0.12 mbar
Smoke temperature
300 °C
Smoke outlet
Ø 18 cm
Fire box dimensions
Net weight
External combustion air outlet
cm² 150
CO emission in smoke (13 %O
2
) 0.08%
Massive smoke capacity
12 g/s
Flue pipe
Up to 5 m
20x30 cm Ø22
Between 5 and 7 m
20x20 cm Ø20
Over 7 m
18x18 cm Ø18
Note
584
1
3
2
8
-1
3
4
8
4
1
1
5
7
7
3
4
0
-3
6
0
475
2
0
-4
0
748
700
515
Ø180
4
9
1
2
6
2
Intermittent combustion unit
* Data may vary according to the fuel used
Airsystem F60
Technical specifications
Fuel type
Wood - Logs
Hourly consumption
3.1 kg/h – 2.2 kg/h
Nominal thermal power
kW 10 Kcal 8600
Efficiency 74.8%
Heatable volume *
215/40 - 246/35 - 287/30
Minimum draught
12 Pa / 0.12 mbar
Smoke temperature
300 °C
Smoke outlet
Ø 18 cm
Fire box dimensions
Net weight
External combustion air outlet
cm² 150
CO emission in smoke (13 %O
2
) 0.08%
Massive smoke capacity
12 g/s
Flue pipe
Up to 5 m
20x30 cm Ø22
Between 5 and 7 m
20x20 cm Ø20
Over 7 m
18x18 cm Ø18
Note
491
475
1
3
2
8
-1
3
4
8
2
0
-4
0
4
1
1
5
7
7
3
4
0
-3
6
0
748
700
515
Ø180
2
6
2
4
9
1
Intermittent combustion unit
* Data may vary according to the fuel used