5-HYDRAULIC CONNECTION

WATER CHARACTERISTICS

The characteristics of the water used to fill the system are very important to prevent the build-up of mineral salts and the formation of

incrustations along the pipes, in the boiler and in the heat exchangers.

Therefore, please GET YOUR PLUMBER'S ADVICE CONCERNING:

Hardness of water circulating in the system, to prevent problems of incrustation and limescale, especially in

the domestic water heat exchanger. (> 25° French).

Installation of a water softener (if water hardness exceeds 25° French).

Filling the system with treated water (demineralised).

Possibly providing an anti-condensation circuit.

Installation of plumbing bumpers to prevent banging along the fittings and pipes.

If you have very extensive systems, with a large amount of water, or which require frequent refilling, the installation of water softening

systems.

It should be remembered that incrustations drastically reduce performance due to low thermal conductivity.