18-CLEANING

END-OF-SEASON SHUTDOWN

At the end of each season, before switching the product off, it is recommended to remove all the pellets from the hopper with a vacuum

cleaner with a long pipe.

When not in use the appliance must be disconnected from the mains power supply. It is recommended to remove the

power cable for additional safety, especially in the presence of children.

The service fuse may have to be replaced if the control panel display does not switch on when the product is switched on again by pressing

the main switch on its side.

There is a fusebox on the side of the product, near the power socket. Open the fusebox cover with a screwdriver and replace the fuses if

necessary (3.15 A delayed) - seek assistance from an authorised and qualified technician.

CHECKING THE INTERNAL COMPONENTS

ATTENTION!

The internal electromechanical components must only be checked by qualified personnel whose technical expertise

includes combustion and electricity.

We recommend that an annual maintenance service is carried out with a scheduled service contract. This service is essentially a visual and

functional inspection of the following components: The following is a summary of the checks and/or maintenance that are indispensable

for the correct operation of the product.

PARTS/INTERVAL

1 DAY

2-3 DAYS

15/20 DAYS

1 YEAR

Brazier

.

Ash pan

.

Glass

.

Upper exchanger

·

Lower exchanger

·

Smoke duct

·

Gaskets

·

Air filter

·

Remote control battery

·