MAINTENANCE

The flue must be kept clean, since the deposit of soot or unburned oils reduces the cross-section reducing the draft and thus compromising

the efficient functioning of the heater and, if large build-ups accumulate, can catch fire. The flue and chimney must be cleaned and

checked by a qualified chimney sweep at least once a year. Once the maintenance has been performed, request a written declaration that

the device is safe.

Failure to clean the system jeopardises the safety.

CHIMNEY

The chimney is a crucial element for the heating appliance to work properly: we recommend a wind proof chimney (A), see Figure 7.

The area of the opening for smoke extraction must be at least double the cross-section of the smoke duct/flue system, and arranged so

that smoke extraction is ensured even

in strong wind. The chimney must

prevent rain, snow or animals from

entering the chimney. The height of

outflow into the atmosphere must be

beyond the reflux zone created by the

shape of the roof or any obstacles near

the outlet (see Figures 2-3-4-5-6).

CHIMNEY COMPONENTS

KEY:

(1) CHIMNEY

(2) REFLUX CHANNEL

(3) SMOKE DUCT

(4) THERMAL INSULATION

(5) OUTSIDE WALL

(6) CHIMNEY CONNECTION

(7) SMOKE CHANNEL

(8) HEAT GENERATOR

(9) INSPECTION ACCESS PANEL

FIGURE 7