2. An anchor hole is provided in the two bottom side members

of the grate frame. After centering the grate correctly, mark

the hole positions on the fireplace/firebox floor. Drill three (3)

5/32" diameter holes approximately 1-1/2" deep for masonry

screws or three (3) 1/8" holes for sheet metal screws.

Note: Do not use the mounting hole underneath the pilot.

Installing a screw there may damage the pilot.

3. Anchor the grate to the fireplace/firebox floor using the screws

provided. Refer to Figure 10.

Proper installation of the grate is essential to prevent any move-

ment of the gas logs and controls during operation.

Figure 10

Notice: (Damper Clamp Installation)

When installing your log set as a vented installation the damper

clamp must be used.

When installing your log set as a vent-free installation the damper

clamp can be used to eliminate the potential for odors when burning

the logs for the first time.
Installing Damper Clamp (Figure 9)

Remove all ashes or other debris from the fireplace. If the fireplace

is equipped with an ash dump be sure to seal the door with furnace

cement or high temperature silicone. Be sure to check the damper

for proper operation and verify that the flue passageway is open.
Place the clamp over the lip of the damper and tighten the hold

down bolt until the clamp is securely attached to the damper. This

will prevent the damper from accidentally closing.
Manual and millivolt controlled gas logs may be installed as a

vented decorative log set in compliance with ANSI Z21.60 and

National Fuel Gas Code. When the gas logs are operated with the

damper open, non-combustible material and minimum mantel

requirements do not apply.

• Turn off the gas supply to the fireplace or firebox.

• Seal any fresh air vents and/or ash clean-out doors located on

the floor or wall of the fireplace. If left unsealed, drafting may

cause pilot outage or sooting. Use a heat resistant sealant. Do

not seal the chimney flue damper.

Before installing in a solid fuel burning fireplace, the chimney flue

and firebox must be cleaned of soot, creosote, ashes and loose paint

by a qualified chimney cleaner.

You must secure the gas log heater to the fireplace floor. If

not, the entire unit may move when you adjust the controls.

Movement of unit may cause shifting of the gas logs which

leads to sooting and improper burning. Grate movement

could cause a gas leak.
Special care is required if you are installing the unit into a

sunken fireplace. You must raise the fireplace floor to allow

access to gas log controls. This will insure adequate air flow

and guard against sooting. Raise the fireplace floor using

noncombustible materials.

Assembly Procedure: (Figure 10)

1. Center the gas log unit in the fireplace or firebox. Make cer-

tain the front feet of the grate sit inside the front edge of the

fireplace or firebox.

Figure 9

INSTALLING AS A VENTED APPLIANCE

BEFORE FULLY INSTALLING THE APPLIANCE

DAMPER CLAMP

DAMPER

TYPICAL FIREPLACE

ANCHOR SCREWS

ANCHOR SCREWS