beautypg.com

Sealey AK450DX User Manual

Ak457d, Ak450dx, Oil drainer unit models no

background image

INSTRUCTIONS FOR:

OIL DRAINER UNIT
Models No:

AK457D

&

AK450DX

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions

and properly maintained, give you years of trouble free performance.

1. SAFETY INSTRUCTIONS

2.1. Description.

Drainers are steel fabricated and have a 75 litre reservoir with telescopic steel funnel fitted with filter

grid and drum full device.

Model AK457D is fitted with a gravity drain tap at the rear of the unit.

Model AK450DX has a dry-fit male coupling for connection to wall mounted air pump AK450DP.

2.2. Application.

Drainer units are designed to collect waste oil of fluids via the vertically adjustable collection bowl.

Drainers are not suitable for vehicles above 3.5 tons for which you should use AK464DX or AK465D.

2. DESCRIPTION & APPLICATION

IMPORTANT

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS. USE

THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE

DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. RETAIN THESE INSTRUCTIONS FOR FUTURE USE.

3. SPECIFICATIONS & ASSEMBLY

Assembly. (see parts diagram fig 1).

1.

Unscrew the complete axle assembly from the transportation position. Use the nuts, bolts, and

washers that are provided to fit the axle assembly and position the castor wheels as illustrated

in the parts diagram.

2.

Screw the drainage tube (item 3) into the collection bowl (item 2).

3.

Introduce the drainage tube through the height adjustment adaptor into the reservoir and

tighten the scalloped hand wheel (item 4).

4.

Place the filter into the collection bowl (item 1).

3 Replace damaged parts. Use genuine parts only. Non authorised parts may be dangerous and will invalidate the warranty.

3 Keep the drainer clean and in good condition for best and safest performance.

3 Wear appropriate protective clothing.

3 Use drainer in an appropriate working area for its function. Keep area clean and tidy and free from unrelated materials and ensure

there is adequate lighting.

3 Ensure the floor is not slippery and wear non slip shoes.

3 Keep children and unauthorised persons away from the working area.

3 Dispose of waste liquids in accordance with local authority regulations.

p WARNING! DO NOT allow uncontrolled discharge of fluids thus polluting the environment.

7 DO NOT position drainer in such a way that it will cause potential hazards when moving, holding

for draining or storing.

s

s IMPORTANT: AK450DX must be used in conjunction with a wall mounted air pump, model no: AK450DP

in order to discharge waste oil (not supplied with this unit).

AK457D Specifications.
Maximum capacity . . . . . .75 litres

Min Height . . . . . . . . . . . .1180mm

Max Height . . . . . . . . . . .1750mm

Length . . . . . . . . . . . . . . . .590mm

Width . . . . . . . . . . . . . . . . .600mm

Discharge . . . . . . . . . . . . . .Gravity

Net weight . . . . . . . . . . . . . . .29kg

AK450DX Specifications.
Maximum capacity . . . . . .75 litres

Min Height . . . . . . . . . . . .1180mm

Max Height . . . . . . . . . . .1750mm

Length . . . . . . . . . . . . . . . .590mm

Width . . . . . . . . . . . . . . . . .600mm

Discharge . . . . . . . . . . . .air pump

Net weight . . . . . . . . . . . . . . .29kg

4.1.

Collection of waste oil

4.1.1. If unit has been used to drain a previous vehicle, check the oil level indicator float to ensure there is sufficient remaining capacity left

before you use the unit. If model AK457D is empty, ensure the evacuation tap is closed before you use the unit.

4.1.2. Place the unit under the raised vehicle and adjust the collection bowl to the desired height and tighten the scalloped hand wheel

of the adjustable height adaptor.

4.2.

Evacuation of waste oil from unit. WARNING! ensure all waste is disposed of in accordance with local regulations.

4.2.1. AK457D position the gravity drain tap over a suitable outlet and open the tap.

4.2.2. AK450DX take the discharge hose of wall mounted pump unit AK450DP and connect the female coupling to the male coupling

of the pan unit and evacuate waste accordingly.

4. OPERATING INSTRUCTIONS

Drainer parts: (see parts diagram fig 1).
Reservoir with handle (item 5). 2 castor wheels (item 8 and 9). 2 rear wheels (item 14).

Adjustable collection bowl with drainage tube (items 2 & 3).

AK457D Gravity drain tap (item 15).

AK450DX Quick release connector (item 15).

AK457D & AK450DX - 2 - 020304