Specifications 2. specific safety & usage – Sealey TR1000 User Manual
Page 2
2.1.
The Tool Rating (kVA) marked on the transformer data plate is the rating assuming a 25% duty factor on a 20 minute cycle i.e. 5
minutes equipment use followed by 15 minutes rest.
2.2.
Check the equipment rating
and operation against the transformer rating. The transformer will supply intermittently used equipment
up to the plate rating but if the equipment is used continuously then the transformer rating should be halved. See Section 3.
2.3.
It is normal for the transformer to get warm during use, particularly if being used continuously, so care should be taken to place
only on surfaces that will not be damaged by the heat.
2.4.
A temperature sensitive cut-out switch is fitted to prevent overheating. If this switch trips, determine and rectify the cause of
overheating and allow time for the transformer to cool before pressing the reset button. (Located on one of the sides adjacent to the
output sockets)
2.5.
The transformer should be plugged directly into a 230V mains socket and should not be supplied via an extension lead. Any
necessary extension lead should be between the transformer and the tool/equipment. Extension leads are available from your Sealey
dealer.
2.6.
The transformer is not double insulated and the safety screen between primary (230V) and secondary (110V) windings is connected to
the earth core of the power cable. for these reasons it is extremely important to confirm that the power socket to be used is reliably
and permanently earthed.
2.7.
Tool transformers can draw a very high initial current when switched on. If fuse failure occurs at switch-on check that the fuse is a
13 amp, anti-surge type. Any circuit breaker protecting the supply socket should have a type 4 tripping characteristic.
2.8.
Do NoT exceed 1.5kV when flash testing.
2.9.
A plug suitable for the transformer output is available from your supplier under Sealey Model No: TR110VP.
3. SPECIFICATIoNS
2. SPECIFIC SAFETY & USAGE
moDEL No:
TR1000.V3 TR1500.V3 TR2000.V3 TR3000.V3
Input Voltage - 1ph AC
230
230
230
230
output Voltage -
1ph AC
110
110
110
110
output Rating - (VA)
Tool (Intermittent)
1000
1500
2000
3000
output Rating - (VA)
Continuous
500
750
1000
1500
output Sockets
1
2
2
2
noTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
ImPoRTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFoRmATIoN: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
01284 703534
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park
,
Bury St. Edmunds, Suffolk,
IP32 7AR
www.sealey.co.uk
Web
Original Language Version
TR1000.V3, TR1500.V3, TR2000.V3, TR3000.V3 Issue: 2 - 12/01/10