beautypg.com

Sealey ML36230F User Manual

Fluorescent floor light, Recommended fuse rating: 3a, Safety instructions instructions for

background image

1. SAFETY INSTRUCTIONS

instructions for:

FlUORESCENT FlOOR lIghT

model n

o

:

Ml36230F

thank you for purchasing a sealey product. manufactured to a high standard this product will, if used according to these instructions and

properly maintained, give you years of trouble free performance.

IMPORTANT: PlEASE READ ThESE INSTRUCTIONS CAREFUllY. NOTE ThE SAFE OPERATIONAl REQUIREMENTS, WARNINgS, AND

CAUTIONS. USE ThIS PRODUCT CORRECTlY, AND WITh CARE FOR ThE PURPOSE FOR WhICh IT IS INTENDED. FAIlURE TO DO SO

MAY CAUSE DAMAgE AND/OR PERSONAl INJURY AND WIll INVAlIDATE ThE WARRANTY.

3. SPECIFICATION

2. INTRODUCTION

fluorescent tubes mounted in impact resistant head. the light unit is supported on a folding steel floor stand. fitted with Bs approved plug

and 5mtr lead.

model no: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ml36230f

Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 x 18W

supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V - 50Hz - 3A

min/max. Height: . . . . . . . . . . . . . . . . . . . . . . . . 1785/2330mm

1.1

ElECTRICAl SAFETY

WARNINg! it is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and

any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of

appropriate safety devices. A residual current circuit Breaker (rccB) should be incorporated in the main distribution board. We also

recommend that a residual current device (rcd) is used. it is particularly important to use an rcd with portable products that are

plugged into a supply which is not protected by an rccB. if in any doubt consult a qualified electrician. You may obtain a residual

current device by contacting your sealey dealer.

You must also read and understand the following instructions concerning electrical safety.

1.1.1 the electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified

electrician, using a Portable Appliance tester (PAt), at least once a year.

1.1.2 the Health & safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances

and the safety of the appliance operators. if in any doubt about electrical safety, contact a qualified electrician.

1.1.3 ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. see 1.1.1 and 1.1.2

and use a Portable Appliance tester.

1.1.4 ensure that cables are always protected against short circuit and overload.

1.1.5 regularly inspect power supply cables and plugs for wear or damage and check all

connections to ensure that none is loose.

1.1.6 important: ensure that the voltage marked on the appliance matches the power supply

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7

DO NOT pull or carry the appliance by the power cable.

1.1.8

DO NOT pull the plug from the socket by the cable.

1.1.9

DO NOT use worn or damaged cables, plugs or connectors. immediately have any faulty

item repaired or replaced by a qualified electrician. When a Bs 1363/A uK 3 pin plug is

damaged, cut the cable just above the plug and dispose of the plug safely.

Fit a new plug according to the following instructions (UK only).

a) Connect the gREEN/YEllOW earth wire to the earth terminal ‘E’.

b) Connect the BROWN live wire to the live terminal ‘l’.

c) Connect the BlUE neutral wire to the neutral terminal ‘N’.

d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer

insulation extends beyond the cable restraint and that the restraint is tight. Double insulated products, which are always

marked with this symbol , are fitted with live (brown) and neutral (blue) wires only. To rewire, connect the wires as

indicated above - DO NOT connect either wire to the earth terminal.

1.1.10 Products which require more than 13A are supplied without a plug. in this case you must contact a qualified electrician to ensure

that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket

with your electrician.

1.1.11 if an extension reel is used it should be fully unwound before connection. A reel with an rcd fitted is preferred since any appliance

plugged into it will be protected. the cable core section is important and should be at least 1.5mm², but to be absolutely sure that the

capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use

of 2.5mm² section cable.

1.2

gENERAl SAFETY

DO NOT use the lamp if damaged.

Keep the light and cables in good working order and condition and take immediate action to repair or replace damaged parts.

use recommended parts and accessories only. Use genuine Sealey parts only. Unapproved parts may be dangerous and will

invalidate the warranty.

WARNINg! Disconnect lamp from mains power before changing tubes or performing any maintenance.

DO NOT use lamp close to paint fumes, solvents or other flammable liquids or flammable waste, such as wipes or cleaning rags.

DO NOT fit a fluorescent tube other than the recommended replacement. (seAleY PArt no. Ml36230F.20)

When not in use switch off the lamp and remove plug from power supply.

WARNINg! ensure the lantern is correctly charged before initial use.

DO NOT allow children to use the lantern.

DO NOT use if the battery or the lantern casing is damaged.

When not in use store the lantern in a safe, dry, childproof location.

rePlAcement tuBe:

seAleY PArt no. Ml36230F.20

Original Language Version

ml36230f issue:3(l) - 06/03/14

Recommended

Fuse Rating: 3A

© Jack sealey limited