Sealey ML36110F User Manual
Fluorescent floor light, Instructions for, Model no
1. SAFETY INSTRUCTIONS
1.1.
ELECTRICAL SAFETY
WARNING! Electrical installation of the light must only be carried out by a qualified electrician. Make sure that power
supply cable is correctly connected to earth. It is the user’s responsibility to read, understand and comply with the following:
You must check all electrical equipment and appliances before use, to ensure that they are safe. You must inspect power supply
leads, plugs and all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the
installation of appropriate safety devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution
board. We also recommend that an RCD (Residual Current Device) is used with all electrical products. It is particularly important to
use an RCD together with portable products that are plugged into an electrical supply not protected by an RCCB. If in doubt consult a
qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer. You must also read and understand
the following instructions concerning electrical safety.
1.1.1 The Electricity At Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2 The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of the appliance
and the safety of the appliance operator. If in any doubt about electrical safety,
contact a qualified electrician.
1.1.3 Ensure the insulation on all cables and the product itself is safe before connecting to
the power supply. See 1.1.1 & 1.1.2 above and use a Portable Appliance Tester (PAT).
1.1.4 Ensure that cables are always protected against short circuit and overload.
1.1.5 Regularly inspect power supply, leads, plugs and all electrical connections for wear
and damage, and power connections to ensure that none is loose.
1.1.6 Important: Ensure the voltage marked on the product is the same as the electrical
power supply to be used.
1.1.7
DO NOT pull or carry the appliance by the power supply or output cables.
1.1.8
DO NOT pull power plug from socket by the power cable.
1.1.9
DO NOT use this product with an extension cable.
1.1.10
DO NOT use worn or damage leads, plugs or connections. Immediately replace or have
repaired by a qualified electrician.
1.1.11 Supply: 230Vac 1ph protected by a 16 amp delayed fuse or equivalent breaker, or
110Vac 1ph protected by a 25 amp delayed fuse or equivalent breaker.
1.1.12 Fit a plug according to the following instructions (see diagram at right - 110V plug
shown).
Ensure the unit is correctly earthed via a three-pin 110V 25A or 230V 32A plug
(not supplied) to suit supply (see 1.1.11).
a) Connect the grEEn/YElloW earth wire to the earth terminal .
b) Connect the broWn live wire to the live terminal ‘l’.
c) Connect the bluE neutral wire to the neutral terminal, unmarked.
d) After wiring, check that there are no bare wires, that all wires have been
correctly connected, that the cable outer insulation extends past the cable
restraint and that the restraint is tight.
WArnIng! Reminder, the electrical installation of the light must only be carried out by a qualified electrician. Make sure that power
supply cable is correctly earthed.
WArnIng! Be very cautious if using a generator to power the light. The generator must be self-regulating and stable with regard to
voltage, wave form and frequency. The output must be greater than the power consumption of the light. If any of these requirements
is not met the electronics within the light may be affected.
note: The use of an unregulated generator may be dangerous and will invalidate the warranty on the light.
1.2
GENERAL SAFETY
Keep the light, cables, holder and clamps in good working order and condition and take immediate action to repair or replace
damaged parts.
Use recommended parts and accessories only. Unapproved parts may be dangerous and will invalidate the warranty.
Only use the electrode holder provided with the system and ensure any replacement is of the same type.
WARNING! Disconnect light from mains power before changing tubes or performing any maintenance.
Replace or repair damaged parts. Use genuine Sealey parts only. Unauthorised parts may be dangerous and will invalidate the
warranty.
Maintain the light in good condition.
DO NOT use the light if damaged.
DO NOT use light close to paint fumes, solvents or other flammable liquids or flammable waste, such as wipes or cleaning rags.
DO NOT fit a fluorescent tube other than the recommended replacement. (SEALEY PART NO. ML36110F.FB)
When not in use switch off the light and remove plug from power supply.
DO NOT allow children to use the light.
When not in use store the light in a safe, dry, childproof location.
INSTRUCTIONS FOR:
FLUORESCENT FLOOR LIGhT
MODEL NO:
ML36110F
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPorTAnT: PLEASE READ ThESE INSTRUCTIONS CAREFULLY. NOTE ThE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND
CAUTIONS. USE ThIS PRODUCT CORRECTLY, AND WITh CARE FOR ThE PURPOSE FOR WhICh IT IS INTENDED. FAILURE TO DO SO
MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE ThE WARRANTY.
Original Language Version
ML36110F Issue: 2 - 23/07/10