beautypg.com

Sealey ML300C User Manual

Floodlight 400w, Ml300c.v3, Instructions for

background image

InstructIons for:

floodlight 400W

MoDEL no:

Ml300C.V3

thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and

properly maintained, give you years of trouble free performance.

IMPORTANT: PlEASE REAd thESE iNStRUCtioNS CAREfUllY. NotE thE SAfE oPERAtioNAl REQUiREMENtS, WARNiNgS, ANd

CAUtioNS. USE thiS PRodUCt CoRRECtlY, ANd With CARE foR thE PURPoSE foR WhiCh it iS iNtENdEd. fAilURE to do So

MAY CAUSE dAMAgE, oR PERSoNAl iNJURY, ANd Will iNVAlidAtE thE WARRANtY.

1. SAfEtY iNStRUCtioNS

1.1.

ElECtRiCAl SAfEtY

p

WARNiNg! it is the user’s responsibility to read, understand and comply with the following:

You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads,

plugs and all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of

appropriate safety devices. An rccB (residual current circuit Breaker) should be incorporated in the main distribution board.

You must also read and understand the following instructions concerning electrical safety.

1.1.1. the Electricity At Work Act 1989 requires all portable electrical appliances, if used on

business premises, to be tested by a qualified electrician, using a Portable Appliance

tester (PAt), at least once a year.

Ensure the light is connected to an appropriate electrical on/off switch.

1.1.2. the Health & Safety at Work Act 1974 makes owners of electrical appliances

responsible for the safe condition of the appliance and the safety of the

appliance operator. If in any doubt about electrical safety, contact a qualified

electrician.

1.1.3. Ensure the insulation on all cables and the product itself is safe before connecting to the

power supply. see 1.1.1. & 1.1.2. above and use a Portable Appliance tester (PAt).

1.1.4. Ensure that cables are always protected against short circuit and overload.

1.1.5. regularly inspect power supply, leads, plugs and all electrical connections for wear and

damage and especially power connections to ensure that none is loose.

1.1.6. Important: Ensure the voltage marked on the product is the same as the electrical power

supply to be used, and check that plugs are fitted with the correct capacity fuse. see fig.2.

1.1.7.

do Not pull power cable once installed.

1.1.8.

do Not pull power plugs from sockets by the power cable.

1.1.9.

do Not use worn or damaged leads, plugs or connections. Immediately replace or have

repaired by a qualified Electrician.

Ensure the unit is correctly earthed and wired according to the diagram figure 1.

a) Connect the gREEN/YEllOW earth wire to the earth terminal ‘E’.

b) Connect the bROWN live wire to live terminal ‘l’.

c) Connect the bluE neutral wire to the neutral terminal ‘N’.

After wiring, check there are no bare wires, that all wires have been correctly

connected and that the wire restraint is tight.

1.2.

gENERAl SAfEtY

WARNiNg! disconnect light from the power supply before changing accessories, servicing

or performing any maintenance.

Maintain the light in good condition. repairs must only be undertaken by a qualified electrician

(use an authorised service agent).

replace or repair damaged parts. use recommended parts only, unauthorised parts may be

dangerous and will invalidate the warranty.

Keep a minimum distance of 1 metre from the front of light to the surface which is to be illuminated. floodlights give off intense heat.

Locate the light in an adequate area for its function, keep area clean and tidy and free from unrelated materials.

If you use an extension lead the cable must be fully unwound from the drum.

the light is weather proof and may be used out doors. Ensure any extensions and plugs are weatherproof.

Allow power cables to run down the length of the light stand to the floor.

do Not allow power cables to hang from lights above floor level.

If the light uses a clamp to support it during use, ensure that the object to which you clamp it is strong enough.

dANgER! do Not direct the light into a person’s eyes. All models have a very intense light output which, if incorrectly used,

could cause eye damage.

do Not touch the light when operating. Allow to cool before touching, light operates at high temperature.

do Not handle halogen bulbs as the natural oil from your fingers will shorten the bulb life. Handle only with a soft dry cloth.

do Not use the light without the front glass shield. Avoid touching the glass shield as handling may reduce its serviceable life and cause

the glass to crack.

do Not use the light without the weather seals intact.

do Not use the light near flammable, combustible or explosive liquids, solids, gases or equipment.

When not in use, switch off the light and disconnect from the power supply. Ensure that the unit is cool and dry and then store in a safe,

dry, childproof area.

fig.1

Yellow & green

Earth Wire

230V

fUSE RAtiNg

5

AMP

fig.2

brown

live

Wire

Cable

Restraint

blue

Neutral

Wire

Original Language Version

ML300c.V3 Issue: 1 - 31/12/10