beautypg.com

Routine cleaning and maintenance – Enviro C-10608 User Manual

Page 9

background image

Routine Cleaning and Maintenance

ASH PAN (weekly)

This part is located under the burner, in the pedestal, and has a latching mechanism to secure it. To

remove the ash pan, open the cover from the right hand side, unlock the latch on the pedestal cover and

pull the pan out. Dump the ashes into a metal container stored away from combustibles. Monitor the ash

level every week. Remember that different pellet fuels will have different ash contents. Ash content is a

good indication of fuel efficiency and quality. Refer to “Warnings and Recommendations” for disposal of

ashes. Vacuum the inside of the ash pan compartment inside the pedestal including the hole at the top
back of the compartment. Replace the ash pan and close pedestal door.

DO NOT PLACE UNBURNED

OR RAW PELLET FUEL IN ASH PAN.

DOOR GLASS CLEANING (2-3 days)

Cleaning of the glass must only be done when stove is cold. Open the door by lifting the handle. The glass

can be cleaned by wiping down the outside and inside of the glass with a dry soft cloth.

If the glass has build up that can not be removed with only the cloth, clean the glass using paper towel

and a gas appliance glass cleaner, this may be purchased through most dealers. If a gas appliance glass

cleaner is not available, use a damp paper towel dipped in fly ash to clean the glass. After the glass has

been cleaned use the dry soft cloth to wiping down the outside and inside of the glass.

FRESH AIR INTAKE (biannually)

Inspect periodically to be sure that it is not clogged with any foreign materials.

EXHAUST PASSAGES (biannually)

Removal of the firebox backing for bi-annual

cleaning

• Open the door by lifting the handle, remove the

burn pot and burn pot liner.

• Lubricate all screws with penetrating oil.

• Remove the four (4) screws that hold the side

panels in place.

• With the tip of a flat screwdriver, gently lift up the

side panels and remove the side panels.

• Pull the center panel out.

• Vacuum thoroughly.

Installation of firebox backing:

• Insert center panel.

• Place the side panels back into the firebox and re-

install the two (2) screws on each side.

• Replace the glass door and secure.

• Clean thoroughly.

Vacuum inside ash

box compartment.

Heat exchanger tubes

cleaner handle.

9

Figure 3: EF5 Open