Outside fresh air is mandatory when installing this unit

in airtight homes and mobile homes.

A Fresh-air intake is strongly recommended for all

installations. Failure to install intake air may result in

improper combustion as well as the unit smoking during power

failures.

When connecting to an outside fresh air source, do not use

plastic or combustible pipe. A 15⁄8” minimum (42 mm) ID (inside

diameter) steel, aluminum or copper pipe should be used. It is

recommended, when you are installing a fresh air system, to

keep the number of bends in the pipe to a minimum.