Clearances to combustibles, Alcove clearances, Installation – Enviro C-10608 User Manual

Page 13

background image

13

Installation

C

LEARANCES

TO

C

OMBUSTIBLES

:

This unit can be installed on a combustible floor due to the built in pedestal hearth pad (for example

linoleum, hardwood flooring). If this unit is to be installed onto a carpeted surface, a hearth pad must

be used for stability.

A

LCOVE

C

LEARANCES

:

This unit may be installed in an alcove. Maintain

these clearances to combustibles.

Minimum Alcove width

48 inches (122 cm)

Minimum Alcove height

48 inches (122 cm)

Minimum Alcove depth

48 inches (122 cm)

Install vent at clearances specified by

the vent manufacturer.

��

��

���� ����

��

���

��

� �

���

��

������

��

�������

�� �������

48"

(122cm)

48"

(122cm)

48"

(122cm)

These dimensions are minimum clearances

but it is recommended that you ensure

sufficient room for serving, routine cleaning

and maintenance.

Side wall to unit 6 inches (15 cm)

Back wall to unit 3 inches (7.5 cm)

Corner to unit

3 inches (7.5 cm)

Figure 6: EF5 Clearance to Combustibles.

Figure 7: EF5 Minimum Alcove Size.