Operation / Maintenance and care

Operation

Remove the „+“ pole clamp (red)

14

from the

„+“ pole of the battery.

Measuring STANDBy / Battery

voltage

After connection to the grid, the appliance is on
STANDBY. The standby display

6

lights up. When

the clamps are connected, the battery voltage is
shown in the LCD (voltage display

9

). The segments

of the condition display

8

are empty.

If the voltage is below 3.8 V or above
15 V, the battery will not be charged. The
display briefly shows the error message
„Err“. The appliance goes on standby.

e® ®

88.8

V

6 V battery
If the voltage range of the battery is measured as
between 3.7–7.3 V, only programme 1 can be se-
lected.

12 V batteries:
If a battery is recognised in the critical voltage
range of between 7.3–10.5 V, the appliance checks
whether a fully charged 6 V battery, or a discharged
12 V battery is present. After pressing the programme
selection button

10

to select a programme, the ap-

pliance carries out a control measurement for about
90 sec.
The display shows:

---

88.8

V

If after about 90 sec. between 7.3–7.5 V are detected,
the 12 V battery is defective.
The appliance goes on standby.

Revitalising

If after about 90 sec. between 7.5–10.5 V are de-
tected, a 12 V battery is present.
Charging starts with a pulse charge for revitalising.
The voltage display

9

flashes. Once 10.5 V are

reached, the appliance switches to the other charge
steps.
Revitalising is the same for all the 12 V charge pro-
grammes.

Programme selection

NOTES:
If a battery is detected in the voltage range of be-
tween 3.7–7.3 V, the programmes 2–3–4 can be
selected.
The charging process takes place automatically.
Depending on the selected programme, the char-
acteristic charge curve is monitored for voltage,
time and temperature. Included are the diagnostics
programme, revitalising mode and retention charge.

(See principle representation programme 3 Fig. C)

Programme

max. (V)

max. (A)

1 6 V

7.3 V

0.8 A

2

*

14.4 V

0.8 A

3

*

14.4 V

3.8 A

4

*

14.7 V

3.8 A

Programme 1 „6 V“

(7.3 V / 0.8 A)

For charging 6 V batteries with a capacity of less
than 14 Ah.

Press the programme selection button

10

, to se-

lect programme 1. The symbol „6 V“ is displayed
on the LCD. During charging, the charge dis-
play

7

flashes and shows the progress of the

charge procedure (1–4 bars). When the battery