Trouble Shooting
TROUBLE
PROBABLE CAUSE
SUGGESTED REMEDY
1. Fan will not
1. Fuse or circuit breaker
1. Check main and branch circuit fuses
start.
blown.
or circuit breakers.
WARNING: Make sure main power
is turned off.
2. Loose power line
2. Check line power connections to fan.
connections to the fan
3. Fan/Light Wall Control is OFF.
3. Turn ON Fan/Light Wall Control.
4. Code switches in remote control
4. Check that both code switches
receiver and Fan/Light Wall Control
are set in the same positions.
are not set in the same position
2. Fan sounds
1. Screws securing fan blade
1. Check to make sure the
noisy.
flanges to motor hub are
screws which attach the
loose.
blade flanges to the motor
hub are tight.
2. Screws holding blades to
2. Tighten screws securely.
flanges are loose.
3. Fan wobbles
1. Screws securing fan blade
1. Check to be sure screws
flanges to mounting hub
which attach the fan blade
are loose.
flanges to the mounting hub
are tight.
2. Fan blade flanges not
2. Check to be sure that the
seated properly.
fan blade flanges seat firmly
and uniformly on the motor
hub. If flanges are seated
incorrectly, loosen the flange
screws and retighten.
3. Mounting plate and/or
3. Tighten the mounting plate
ceiling outlet box is not
screws to the outlet box,
securely fastened.
and/or secure outlet box.
4. Fan blades out of balance.
4. Interchanging an adjacent
(side-by-side) blade pair can
redistribute the weight and
result in smoother operation.
Or use supplied balancing
kit to balance blades.
WARNING:
FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX
OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.
!
!