Warning, Installation of wall control, Way installation – Emerson CF730 User Manual
Page 10: Single-pole installation
4. Install a wall control in the wall box
containing the “hot” wire first. Connect
the black wire of the wall control to the
“hot” wire. Securely connect wires with
wire connectors supplied.
5. Connect one black wire of the wall
control to both remaining traveler wires
in the wall box and secure with wire
connector supplied.
4. Connect one black wire of wall control
to the “hot” wire. Securely connect
wires with wire connectors supplied
(Figure 16).
5. Connect one black wire of wall switch
to the “load” (black) wire in wall box.
Securely connect wires with wire
connector supplied.
6. Screw wall control into wall box and
install decorator style faceplate
(included). Leave wall control in “OFF”
mode until fan installation is completed.
7. Refer to page 4 and complete the
ceiling fan installation.
10
Do not connect any neutral (white)
wire to this control. Incorrect wiring
will damage this control.
!
WARNING
EMERSON
®
HI
MED
LOW
FAN OFF
LIGHT
ON
OFF
BLACK
BLK
HOT
FAN/LIGHT
WALL
CONTROL
WALL
BOX
TO LOAD
TO
120VAC
SOURCE
G
RO
UN
D
Figure 16
3-WAY INSTALLATION
(On fan controlled by two different wall
controls) (See Figures 17 and 18.)
1. Disconnect power at circuit breaker or
remove fuse.
2. At all wall box locations remove
faceplates and screws from existing
controls. Pull controls out from wall
boxes and determine which wall box
contains the “hot” lead and which wall
box contains the “load” wire. Also,
identify traveler wires which are
common to both wall boxes.
Disconnect wires from existing controls
only. Do not attempt to disconnect any
wires not already connected to existing
controls.
Installation of Wall
Control
SINGLE-POLE INSTALLATION
(Figure 15)
1. Disconnect power at circuit breaker or
remove fuse.
2. Remove faceplate and screws from
existing wall control. Pull control out
from the wall box. Determine the “hot”
wire and the “load” wire and disconnect
these wires from control. Do not
attempt to disconnect any wires not
already connected to existing control.
3. Before installing wall control, place wall
control in “OFF” mode by pushing
“ON/OFF” switch to the “OFF” position.
EMERSON
®
HI
MED
LOW
FAN OFF
LIGHT
ON
OFF
FAN/LIGHT
WALL CONTROL
HOT
BLK
NEUTRAL
BLACK
GROUND
LOAD
BLACK
REMOTE CONTROL
RECEIVER LOCATED
UNDER THE FAN
HOUSING
Figure 15
3. Before installing wall control, place wall
control in “OFF” mode by pushing
“ON/OFF” switch to the “OFF” position.
Do not connect any neutral (white)
wire to this control. Incorrect wiring
will damage this control.
!
WARNING
BP7315 Florissant 3/7/06 8:42 AM Page 10