Operation logic data – Envision Peripherals Geothermal Indoor Split Heat Pumps User Manual

Page 20

background image

20

ENVISION SERIES INSTALLATION MANUAL

OPERATION LOGIC

HEATING

COOLING

FAN ON

SL1 - IN

ON

SL2 - IN

ON

STG1

STG2

STG

EMERG

STG1

STG2

SINGLE SPEED UNITS

Compressor

On

On

On

Off

On

On

-

-

-

Rev Valve

Off

Off

Off

Off

On

On

-

-

-

Loop Pump

On

On

On

Off

On

On

-

On

-

DHW Pump

On

Off

Off

Off

On

On

-

-

-

Secondary 1- Out

On

On

On

Off

On

On

-

-

-

Emerg LED

Off

Off

Off

On

Off

Off

Off

-

-

T-Stat Signal

Y1

Y1, Y2

Y1, Y2, W

W

Y1, O

Y1, Y2, O

G

-

-

DUAL CAPACITY UNITS

Compressor-Lo

On

Off

Off

Off

On

Off

-

-

-

Compressor-Hi

Off

On

On

Off

Off

On

-

-

-

Rev Valve

Off

Off

Off

Off

On

On

-

-

-

Loop Pump

On

On

On

Off

On

On

-

On

-

DHW Pump

On

On

Off

Off

On

On

-

-

-

Secondary 1- Out

On

On

On

Off

On

On

-

-

-

Secondary 2- Out

Off

On

On

Off

Off

On

-

-

-

Emerg LED

Off

Off

Off

On

Off

Off

-

-

-

T-Stat Signal

Y1

Y1, Y2

Y1, Y2, W

W

Y1, O

Y1, Y2, O

G

-

-

Operation Logic Data