Trouble shooting, Gb ie – Florabest FLV 1200 A1 User Manual
Page 14

14
GB
IE
Trouble shooting
Problem
Possible cause
Remedy
Abnormal noises,
clatter or
vibrations
Foreign body on cylinder
(20/21)
Remove foreign body
Damaged sprung tines (20)
or cylinder knives (21)
Exchange cylinder (20/21)
Cylinder (20/21) incorrectly
mounted
Install cylinder (20/21) correctly (see
chapter on exchanging the cylinder)
Toothed-belt slip
Switch device off and pull power
plug. Remove the soil and grass
residues available.
Implement does
not start
No power
Check power socket, cable, line;
repair only by qualified electrician
ON / OFF switch (2)
defective
Repair by After-Sales Service
Carbon brushes worn out
Motor defective
Motor fails
Blocked by foreign body
Remove foreign body
Grass is too long
Mow beforehand; see chapter
“Operation”
Clogged discharge
Clean discharge
Overload protection tripped Allow implement to cool down for
about 1 minute
Work result not
satisfactory
Sprung tines of aerator
cylinder (20) worn out
Exchange cylinder (20/21)
Knives of verticutor cylinder
(21) blunt or damaged
Exchange cylinder (20/21)
Toothed belt defective
Repair by After-Sales Service
Transport Position or
incorrect Working Position
selected
Select Working Position 1 or
Readjust Position 2-4 (see chapter
“Setting the Working Positions)
Grass is too long
Mow beforehand; see chapter
“Operation”