Trouble shooting – Florabest FLB 2500 A3 User Manual
Page 15

15
GB
Trouble shooting
Problem
Possible cause
Fault correction
Device does not
start
Mains voltage is not pres-
ent
Check plug socket, cable, line,
plug and fuse, where appropriate,
repair through electrical specialist
Defective on/off switch
Repair through customer service
Worn carbon brushes
Defective motor
Blowing/suction pipe (2) is
not completely fitted
Install a two-part blowing/suction
pipe
Impeller wheel cover still
open (see
D
No. 25)
Close impeller wheel cover and
screw it down properly
Device works with
interruptions
Damaged power cable
Check cable; where appropriate,
replace
Internal loose connection
Repair through customer service
Defective on/off switch
Low suction capacity
or suction not pres-
ent
Collection bag (18) is full
Empty collection bag
Collection bag is dirty
Clean collection bag
Selector switch (16) in in-
correct position
Set selector switch to the
suction symbol
Device clogged up or
blocked by foreign bodies
Remove plug or blockages (see
chapter Cleaning and Mainte-
nance)
Small or missing
blowing power
Selector switch (16) in in-
correct position
Set selector switch to the
blowing symbol
Airstream regulator (10) in
incorrect position
Rotate airstream regulator to high
position
Device works with
interruptions
Foreign body blocks impel-
ler wheel
Remove blockage (see chapter
Cleaning and Maintenance)