57

GB MT

generation of mold and unpleasant

odours.

• Free the outlet area from possible

shredded residues.

Removal of clogging and

blockage

Leaf material and fresh plant parts may

clog / block the device.

Cleaning the impeller wheel:

Pull out the mains plug!

D

1. Remove the Allen key attached

to the power cable (No.

A

13)

2. Use the key (13) to open the

screw on the impeller wheel

cover (25) and tip up the cover.

3. Carefully remove residues or

clogging materials from the im-

peller wheel (24).

4. Check to make sure the impeller

wheel is easier to turn and is in

undamaged condition. Have our

Service Centre (see address on

p. 17) replace a defective impel-

ler wheel.

5. Screw the cover down tight.

The device cannot be operated

unless the impeller wheel cover

is closed and properly screwed

down.

Cleaning the air outlet area:

1. Remove the collection bag.

2. Clean the external air outlet area on

the device.

3. Set the operating mode selector

switch to the suction symbol.

4. Remove dirt residues in the inner air

outlet area with a bottle brush or simi-

lar. Remove unwieldy objects with a

blunt tool without sharp edges.

Cleaning the blower / suction tube

1. Remove the collection bag loop from

the hook.

2. Remove the fastening screws (see

B

No. 4) and pull off the blower / suction

tube.

3. Knock material out of the inside of the

tube and clean it as required.

4. Remount the tube and reattach the

collection bag loop to the hook.

Replacing the collection bag

Replace a defective collection bag. Employ

only original collection bags (see chapters

“Spare Parts”), otherwise the guarantee

claim is invalid.

Safekeeping

• Keep the leaf blower in a dry, frost-free

location, which is inaccessible to chil-

dren.

• Do not store the device in direct sunlight;

store it in dark or in reduced light condi-

tions.

• Do not cover the device with nylon

bags, since moisture can form.

• Clean the device thoroughly at the

season end and for storage during

wintering. Clean the collection bag by

removing it, emptying it and washing

with warm water and neutral soap. Re-

attach the dried bag again.

• Ensure that all nuts, bolts and screws

are tightened so the equipment is in