Run-time Mode

LCD Display

On power-up, the DC-One boots and displays

the run-time screen. The current preset

memory location and name are displayed as

well as the configuration on which the preset is

based.

Caution

Before operating the sound reinforcement system, and any time a new preset is

recalled, check the configuration display to make sure that it is appropriate for your system

and that connections to your system are correct for the current configuration. Failure to do so

could cause unexpected results or damage to the system or its components.

The LCD display’s contrast can be adjusted in

the Setup Menu to accommodate different

viewing angles.

Input Level Meters

During operation, the left and right input level meters display the

signal present at the DC-One’s analog and Digital inputs. The DC-

One does not itself have input level controls. Proper input level

setting is accomplished by setting the output level from the (L / R)

bus outputs from the connected mixer or other audio source.

Optimal signal-to-noise performance is obtained when the nominal

(average), input level consistently lights the +3dBu (green) and /

or +6dBu (yellow) LED indicators. As the DC-One is a digital audio

device – and digital clipping produces very unpleasant results – the

Clip (red) LED should never light. If it does, reduce the output level

of the connected mixer.

Output Level Meters

Each output channel has an

eight-segment output level

VU meter. Meter response

characteristics can be

selected in the Setup menu:

Normal Fast, Peak-Hold or Slow Decay. The yellow segment indicates that limiting is

being applied to the output channel. It is important to understand how the meters

work and what they are displaying. The Output Meters are displayed as “dB to

Limiter Threshold”. In other words, these meters will display the headroom between

the output level and the limiter threshold. When viewed in conjunction with the Gain

Reduction meters, this provides a complete display of level and headroom before

and after limiting has been engaged to allow system levels to be optimized. This also

means that the output metering will be displayed differently depending on the limiter

threshold setting. The red segments indicates clipping of the D/A converters and

should be avoided by adjusting the Output Level setting of the output channel.