12. INSTALLING THE LIGHT KIT

11. INSTALLING THE SWITCH HOUSING

Mounting plate

Connection plug

Switch housing

Switch housing

Plastic nut

White wire

Black wire

Isolation plate

Nut

Lock washer

Metal washer

Capacitor

Reverse
module

Limiter

LIGH

T/

BL

AC

K

Pow

er

Li

mi

t

Ma

x.1

90

W

(O

N/

OF

F)

Inc

an

de

sc

en

t o

r Ba

lla

st

AC

IN L

/R

ED

AC

IN

N

/W

HIT

E

Mo

de

l No

: PL

-1

90

B

AC

12

0V

60

HZ

NOTE: Before continuing, make sure the power
is disconnected by turning off the circuit breaker

Step 1. Loosen the 3 screws on the switch
house mounting plate.

Step 2. The square plastic wiring connector
from the ceiling fan and the light fixture will only
fit together one way. Match up the color on the
side of the connector, then push them together
until the snap engages.

Step 3. Tuck the connections neatly into the
switch housing. Align the key holes on the
switch housing with the screws on the mounting
plate. Turn the switch housing until it locks in
place at the narrow end of the key holes.
Tighten all 3 screws previously loosened.
(Fig. 19)

Step 1. Remove the finial NUT located in the
center of the switch housing. See Fig. 20.

Step 2. Remove the lock washer, metal washer
and hex nut from the light fixture mounting
stem.

Step 3. Feed the electrical wires from the light
fixture through the hole in the switch housing
(starting with the black wire first, it has a larger

switch housing, add the metal washer, lock
washer and hex nut on the inside of the switch
housing and tighten securely.

NOTE: Please take the reverse module, capaci-
tor and 190w power limiter out of the switch
housing prior to threading the light kit to switch
housing.

or removing the fuse at the circuit box.

connector). Thread the light kit onto the