Connecting the PSM Cables and AC Power Cords
2-6 Installation
Figure 2-2 Fastening the C2RPS-CHAS8 to the Rack
Connecting the PSM Cables and AC
Power Cords
The PSMs are connected to the SecureStack Ethernet switch devices using PSM cables.
To connect the PSMs, proceed as follows:
1.
Connect one end of the PSM cable (shown in
) to the Redundant Power
Supply connector on the switch device. Then connect the other end to the Redundant
Power Supply connector at the rear of the PSM shown in
and
2.
Connect a standard AC power cord to the AC input power connector on the PSM
shown in
, then plug the AC power cord into the main AC power outlet.
3.
The green Power LED on the front of the PSM will glow to indicate a successful
connection. If the LED remains off, proceed as follows:
a.
Check the AC power cord connection at the AC power source and make sure the
power source is within specification.
b. Check the AC power connection to the PSM.
c.
Swap the AC power cord with a known good one.
d. If the green LED continues to remain off, contact Enterasys Networks. Refer to
” on page 1‐5 for instructions. Otherwise, go to step 4.
4.
If two or more power supplies are being installed, repeat steps 1 through 3 for each
PSM.
1 C2RPS-CHAS8 chassis
3 Mounting screws (supplied by user)
2 Rails of 19-inch rack
А
Б
Б
В
В
C2RPS-CHAS8
C2RPS-PSM
Po
w
er
C2RPS-PSM
Po
w
er
C2RPS-PSM
Po
w
er
C2RPS-PSM
Po
w
er
C2RPS-PSM
Po
w
er
C2RPS-PSM
Po
w
er
C2RPS-PSM
Po
w
er
C2RPS-PSM
Po
w
er