ENERGIZER BATTERY MANUFACTURING 

VERSION 1.2 

Section 2:   PP355 Performance Characteristics 

 
 
This section describes the performance of the PP355 battery.  Standard discharge curves, performance 
at a variety of environmental conditions, pulse capability, and service maintenance data are presented.   
 

2.1 ‐‐ Performance at Standard Conditions 

 
Standard  conditions  for  Energizer  Zinc  Air  Prismatic  batteries  are  defined  as  21°C  and  50%  relative 
humidity (RH).  Under these conditions, the PP355 battery is designed to provide continuous discharge 
capability  up  to  100  mW.    While  best  performance  is  obtained  in  standard  conditions  and  continuous 
duty  cycles,  Energizer  Zinc  Air  Prismatic  Batteries  perform  well  over  a  wide  range  of  environmental 
conditions  and  in  intermittent  applications  as  well.    Figure  6  contains  typical  discharge  curves  for  the 
PP355 under standard conditions and constant power loads of 25, 50, 75, and 100 mW. 
 

Figure 6:  PP355 Discharge Curves at Continuous Constant Power 
 

0.8

0.9

1.0

1.1

1.2

1.3

1.4

0

500

1000

1500

2000

2500

Vo

lt

a

ge

 (V

)

Discharge Energy (mWh)

100 mW

75 mW

50 mW

25 mW

 


 
Energizer  Zinc  Air  Prismatic  batteries  significantly  outperform  existing  Alkaline  cylindrical  solutions  of 
equivalent  volume.    To  demonstrate  this  advantage,  Figure  7  shows  how  PP355  and  AAAA  Alkaline 
batteries perform on the same continuous power tests.  The PP355 lasts longer than the alkaline AAAA 
even  though  the  volumes  of  both  battery  types  are  approximately  the  same  at  2.37  cc  and  2.2  cc, 
respectively.