beautypg.com

Energizer battery manufacturing version 1.2, 4 ‐‐ service maintenance – Energizer PP355 User Manual

Page 10

background image

P a g e

 | 10 

 

ENERGIZER BATTERY MANUFACTURING 

VERSION 1.2 

Figure 8:  Pulse Capability of PP355 Batteries 

0.0001

0.001

0.01

0.1

1

0

200

400

600

800

1000

1200

1400

1600

Maxim

u

m

 Pu

ls

Du

ra

ti

o

n

 (s)

Current (mA)

1.1V Cutoff

1.0V Cutoff

0.9V Cutoff

0.8V Cutoff

 

2.4 ‐‐ Service Maintenance 

 
Zinc Air batteries are stored with adhesive backed tabs prior to use.  These tabs seal the air holes against 
oxygen  and  water  ingress.    To  obtain  the  full  battery  performance,  the  tab  should  be  removed  only 
immediately  prior  to  use.    When  the  battery  is  sealed  by  the  tab,  service  loss  due  to  self  discharge  is 
approximately 5% per year.  Figure 10 illustrates the rates at which capacity is lost with the tab on and 
the tab removed. 
 

Figure 10:  Service Maintenance of Energizer Zinc Air Prismatic Batteries 

 

80%

85%

90%

95%

100%

0

1

2

3

4

R

a

te

d Ca

pa

ci

ty

(

%

)

Shelf Life (yr)

unsealed
(tab removed)

sealed
(on tab)