Introduction specifications – Empire Comfort Systems CIVF-25-21 User Manual
Page 5

Page 5
16938-3-0806
Always consult your local Building Department regarding
regulations, codes or ordinances which apply to the installation
of an unvented room heater.
This appliance may be installed in an aftermarket* permanently
located, manufactured (mobile) home, where not prohibited by
state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from
the manufacturer.
This appliance is only for use with the type of gas indicated on
the rating plate.
Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner fill out and mail warranty card
supplied with unvented room heater.
3. Installer should show owner how to start and operate unvented
room heater.
This CIVF-25 is design certified in accordance with American
National Standards Institute Z21.11.2 by the Canadian Standards
Association as an Unvented Room Heater and should be installed
according to these instructions.
Attention: During initial use of ceramic log you will detect an
odor as the ceramic log is cured. Also, during the curing process
the ceramic log will burn with a yellow flame.
Any alteration of the original design, installed other than
as shown in these instructions or use with a type of gas not
shown on the rating plate is the responsibility of the person
and company making the change.
Warning: This appliance is equipped for (natural or propane)
gas. Field conversion is not permitted.
Important
All correspondence should refer to complete Model Number, Serial
Number and type of gas.
Notice: During initial firing of this unit, its paint will bake out, and
smoke will occur. To prevent triggering of smoke alarms, ventilate
the room in which the unit is installed.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment
or accessories and repair and servicing of equipment shall be
performed only by a qualified agency. The term "qualified agency"
means any individual, firm, corporation or company which either in
person or through a representative is engaged in and is responsible
for (a) the installation or replacement of gas piping or (b) the
connection, installation, repair or servicing of equipment, who is
experienced in such work, familiar with all precautions required
and has complied with all the requirements of the authority having
jurisdiction.
State of Massachusetts: The installation must be made by
a licensed plumber or gas fitter in the Commonwealth of
Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental
room heaters shall provide to each purchaser a copy of 527 CMR
30 upon sale of the unit.
The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1/
NFPA 54.*
*Available from the American National Standards Institute, Inc., 11 West 42nd St., New York,
N.Y. 10036.
High Altitudes
For altitudes/elevations above 2,000 feet (610m), ratings should be
reduced at the rate of 4 percent for each 1,000 feet (305m) above
sea level. Contact the manufacturer or your gas company before
changing spud/orifice size.
INTRODUCTION
SPECIFICATIONS
Model
CIVF-25
Input BTU/HR (KW/H) Maximum
30,000 (8.8)
BTU/HR (KW/H) Minimum
21,000 (6.2)
Height
27 3/4" (70.5cm)
Width
25 1/2" (64.8cm)
Depth
15 1/2" (39.4cm)
Gas Inlet
3/8" (9.5mm)
Stove Casting (Must be ordered with Firebox)
CIFB-1
Flat Black
CIPB-1
Porcelain Black
CIPG-1
Porcelain Green
CIPS-1
Porcelain Sand
CIPN-1
Porcelain Navy
CIPR-1
Porcelain Red
Accessories
TMV
Millivolt Wall Thermostat - Reed Switch
FRBC-1
Battery Operated Remote Control
FRBTC-1
Battery Operated Remote Control w/Thermostat
FREC-1
Electric Remote Control
FWS-1
Wall Switch
CIB-2
Automatic BLower
Stone Inlay Replaces Standard Grill Top
CII-2
Stone Inlay
Empress Green
CII-3
Stone Inlay
Hunan Jade
CII-4
Stone Inlay
Gray Botticino
CII-5
Stone Inlay
Azul
CII-6
Stone Inlay
Salome
CII-7
Stone Inlay
Black Swan