10 CLEANING AND MAINTENANCE
Attention! Before performing any work on the equipment, pull the power
plug (1).
10.1
Cleaning
Keep the ventilation slots of the machine clean to prevent overheating of the engine.
Regularly clean the machine housing with a soft cloth, preferably after each use.
Keep the ventilation slots free from dust and dirt.
If the dirt does not come off use a soft cloth moistened with soapy water.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
10.2
Checking and replacing the carbon brushes
The carbon brushes must be checked on a regular basis.
In case of wear, replace both carbon brushes at the same time.
Mount the carbon brush holders.
After mounting new carbon brushes, let the machine run at no load for 15 minutes.
Use only the correct type of carbon brushes.
10.3
Service department
If the connecting cable (or mains plug) is damaged, it must be replaced. Replacement of the
connecting cable should only be carried out by a qualified specialist (qualified electrician).
11 TECHNICAL DATA
POWXQ5313
Rated voltage
230-240V
Rated frequency
50Hz
Rated input
1350W
No load speed
5000min
-1
Max cutting depth 90°
62mm
Max cutting depth 45°
41mm
Blade
185 x 20 x 2.4 mm
Teeth
24T
Degree of protection
IP20
Protection class
Double insulated
Weight
4.16 kg
Construction
Hand-held
Supply connection
Non detachable cord
Rated operation
Continuous operation
12 NOISE AND VIBRATION
Noise emission values measured according to relevant standard. (k=3)
Sound pressure level LpA
92dB(A)
Sound power level LwA
103dB(A)