Z8 Encore!® Evaluation Board
If the IrDA board is installed the Console port is disabled.
Table 10. J7 External Vref
Shunt Status Function
Device or Register Affected
IN
External Vref is used for ADC
Internal Vref is disabled.
OUT
Internal Vref is used for ADC
Internal Vref is enabled.
Table 11. J9 Vref
Function
Device or Register Affected
J9-1
Test point to external Vref
Vref
J9-2
GND
None
Table 12. J10 IrDA Enable/Disable
Shunt Status
Function
Device Affected
IN
IrDA enabled
Only the IrDA interface is operational.
OUT
IrDA disabled
UART0 communicates through RS-232.
If J6 12-14 is IN Port A (3-5) can be
assigned to other functions (console
connector P1 is disabled).
If J6 12-14 is OUT console connector P1
is enabled (Port A (3-5) is assigned to
UART0).