Gas Line Installation (Figure 7)
The gas pipeline can be brought in through the right or left side of the
appliance. Consult the current National Fuel Gas Code, ANSI Z223.1
CAN/CGA-B149 (.1 or .2) installation code.

Recommended Gas Pipe Diameter

Pipe Length

Schedule 40 Pipe

Tubing, Type L

(Feet)

Inside Diameter

Outside Diameter

Nat.

L.P.

Nat.

L.P.

0-10

1/2"

3/8"

1/2"

3/8"

1.3 cm

1.0 cm

1.3 cm

1.0 cm

10-40

1/2"

1/2"

5/8"

1/2"

1.3 cm

1.3 cm

1.6 cm

1.3 cm

40-100

1/2"

1/2"

3/4"

1/2"

1.3 cm

1.3 cm

1.9 cm

1.3 cm

100-150

3/4"

1/2"

7/8"

3/4"

1.9 cm

1.3 cm

2.2 cm

1.9 cm

Note: Never use plastic pipe. Check to confirm whether your local codes
allow copper tubing or galvanized.
Note: Since some municipalities have additional local codes, it is always
best to consult your local authority and installation code.
The use of the following gas connectors is recommended:

ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing
and Fittings

ANS Z21.45 Assembled Flexible Appliance Connectors of Other
Than All-Metal Construction

The above connectors may be used if acceptable by the authority having
jurisdiction. The State of Massachusetts requires that a flexible appliance
connector cannot exceed three feet in length.

1/2 FLEX TUBING

1/2 FLEX TUBING

1/2 NPT

1/2 NPT

NIPPLE

1/2 NPT NIPPLE

1/2 NPT NIPPLE

1/2 NPT UNION

1/2 NPT UNION

1/2 NPT X 1/2

1/2 NPT X 1/2

FLARE FITTING

FLARE FITTING

TEE HANDLE

TEE HANDLE

1/2 NPT CLOSE NIPPLE

1/2 NPT CLOSE NIPPLE

TEE HANDLE

TEE HANDLE

1/2 NPT GAS SUPPLY

1/2 NPT GAS SUPPLY

1/2 NPT X 1/2 FLARE

1/2 NPT X 1/2 FLARE

SHUT OFF VALVE

SHUT OFF VALVE

1/2 NPT SHUT

1/2 NPT SHUT

OFF VALVE

OFF VALVE

RIGID GAS LINE CONNECTION

RIGID GAS LINE CONNECTION

FLEXIBLE GAS LINE CONNECTION

FLEXIBLE GAS LINE CONNECTION

1/2 NPT GAS SUPPLY

1/2 NPT GAS SUPPLY

Figure 7

Note:** Island (C) and Room Divider (D) installation is possible as long
as the horizontal portion of the vent system (H) does not exceed 20 feet
with a minimum vertical run of 8 feet. See details in Venting Section.
*When you install your Direct Vent Fireplace in (D) Room divider or (E)
Flat on wall corner positions, a minimum of 6 inches clearance must be
maintained from the perpendicular wall and the front edge of the
appliance.

Clearance to Combustibles (Figure 6)

2" x 4" HEADER

2" x 4" HEADER

STAND OFF

STAND OFF

3" (76mm) HEIGHT

3" (76mm) HEIGHT

ABOVE TOP OF

FIREPLACE

GLASS FRONT

GLASS FRONT

TOP FRAMING

LEDGE

FINISHED WALL

FINISHED WALL

ADJUSTABLE

NAILING

FLANGES

SEE MANTLE CHART

SEE MANTLE CHART

FOR MAXIMUM MANTLE

FOR MAXIMUM MANTLE

DEPTH

SEE MANTLE CHART

SEE MANTLE CHART

FOR MINIMUM HEIGHT

FOR MINIMUM HEIGHT

OF MANTLE ABOVE UNIT

OF MANTLE ABOVE UNIT

CLEARANCE TO COMBUSTIBLES

CLEARANCE TO COMBUSTIBLES

BACK

0" (0 mm)

BACK

0" (0 mm)

SIDE

0" (0 mm)

SIDE

0" (0 mm)

FLOOR

0” (O mm)

FLOOR

0” (O mm)

TOP STAND OFF

0" (0 mm)

TOP STAND OFF

0" (0 mm)

TOP FRAMING LEDGE

0" (0 mm)

TOP FRAMING LEDGE

0" (0 mm)

Figure 6

Locating Your Direct Vent Gas Fireplace (Figure 5)

Figure 5

Planning Your Installation