Figure 5 Caulk and Install Duct Termination

WALL

DUCT TERMINATION

RAIN CAP

Figure 4 Example of Installation

4. Two cover plates are provided in kit. Use cover plate that

measures 6 3/8" in height. Do not use cover plate that measures
7" in height. Discard 7" cover plate.

5. Insert and position 6 3/8" cover plate into left, interior bottom of

fireplace. The 3/8" diameter hole in cover plate will be positioned
upward and to the left.

6. Insert damper rod through damper rod bracket and 3/8" diameter

hole in cover plate. Insert damper rod into 1/4" diameter hole in
damper door tab. Place smooth side of 1/2" diameter pushnut
over end of damper rod. Press the pushnut onto the damper rod
approximately 1/8". The pushnut will prevent the damper rod
from falling out of 1/4" diameter hole in damper door tab.

7. Attach cover plate to support legs with (4) 10 x 1/2" provided

screws. The support legs are on the left side, to the rear, in the
interior bottom of fireplace.

8. The 1 1/4" offset on damper rod is used to secure the damper

door in an open or closed position.

9. Refer to Figure 4 for options available for installation of 6"

diameter duct. The duct run can be a maximum length of 40 feet.
Insulated duct is recommended when ducting through a heated
space. Note: 6" C vent or 6" flex vent can be used.

10. Cut a 6" diameter hole in structure after determining duct

termination (rain cap) location.

11. Caulk exterior of structure that will be contacted by outside air

tube assembly (See Figure 5).

12. Insert outside air tube assembly into 6" diameter hole in structure.

Align clearance holes on rain cap with clearance holes on outside
air tube assembly. Attach rain cap and outside air tube assembly
to structure with (6) 1 1/2" provided screws.

13. Attach 6" diameter duct to 1 1/2" collar on damper assembly.
14. Route 6" diameter duct to outside air tube assembly.
15. Attach 6" diameter duct to outside air tube assembly.
16. Installation of fresh air intake kit is completed.

PARTS LIST

Part

Part

Quantity

Description

Number

Supplied

Damper Assembly

10098

1

6 3/8" Cover Plate

10083

1

Damper Rod Bracket

10086

1

Rain Cap

10124

1

Damper Rod

R-4182

1

Pushnut

R-4607

1

10 x 1/2" Screw

R-2737

6

10 x 1 1/2" Screw

R-1134

6

NO ELBOWS USED ON FRESH AIR KIT

WHEN 90

°

OR 45

°

ELBOWS ARE USED ON FRESH AIR KIT

CAULKING