OPTIONAL SIMULATED BRICK LINER

INSTALLATION INSTRUCTIONS

Direct Vent Fireplace

BRICK LINER KIT

MODEL NUMBER

DVF- BL-36

DVF-36

DVF-36IP

DVF-BL-42

DVF-42

DVF-42IP

INSTALLING OPTIONAL SIMULATED BRICK PANELS

1. If installed, turn OFF gas supply to fireplace.
2. If installed, remove log assembly from fireplace.
3. The back panel is to be installed before the side panels. Place back

panel against the rear wall in fireplace.

4. Place one side panel against the side wall in fireplace. Align the

brick pattern on back panel and side panel.

5. To install the brick panel (Z) bracket you must first remove the

top and bottom screw on the side of the inner casing front as it
attaches to the outer casing. Now, place the brick panel (Z)
bracket over the front edge of the side panel. The clearance holes
on the brick panel (Z) bracket will align with the top and bottom
screw holes on the side of the inner casing front.
Reattach the top and bottom screws through the clearance holes
on the brick panel (Z) bracket and into the inner casing front.

6. Repeat Step 4 and Step 5 to attach the second side panel to

fireplace.

7. Installation of optional simulated brick panels is completed.

PARTS LIST

Part Description

Kit Number

Kit Number

Quantity

DVF-BL-36

DVF-BL-42

Supplied

Brick Panel (Z) Bracket

10990

10991

2

Brick Panel - Side Right

R-5201

R-5205

1

Brick Panel - Side Left

R-5202

R-5206

1

Brick Panel - Back

R-5200

R-5204

1

SIDE PANEL

SIDE PANEL

SIDE PANEL

SIDE PANEL

BACK PANEL

BACK PANEL

Z BRACKET

Z BRACKET