beautypg.com

Yes no, Positioning, Levelling – Electrolux EKG 60111 User Manual

Page 71: Gas connection

background image

electrolux 71

Positioning

This appliance has been designed to be
placed close to furniture units not
exceeding the height of the working level
(EN 60 335-2-6)

Levelling

The appliance is provided with adjust-
able small feet placed in the back cor-
ners of the base.
By adjusting the small feet it is possible
to ensure a uniform distribution of the liq-
uids contained in pans or pots.

Gas connection

Gas connection must be carried out
according to the rules in force. The
manufacturing company release the unit,
once tested, adjusted for the kind of gas
stated on the rating plate located on the
back of the range, next to connection
pipe. Be sure that you are going to
connect the unit to the same kind of gas
written on the plate.

Connection using a rigid
pipe or a flexible metal pipe

To ensure higher safety, it is
recommended to carry out the
connection to the gas system using rigid
pipes (ex. copper) or using flexible
stainless steel pipes, to avoid any stress
to the unit. Gas feeding pipe fitting is
Gc 1/2. For this type of installation,
connection to the gas supply should be
carried out using only and exclusively
flexible metallic tubes in conformity with
rules in force.

ELECTRIC WIRE

FLEXIBLE RUBBER
GAS PIPELINE

FLEXIBLE RUBBER
GAS PIPELINE

ELECTRIC WIRE

YES

NO