Multi-zone Heat Pump Condensing Units

5. With a screw-

driver punch

out and re-

m o v e t h e

knock-outs in

the low & high

Volt electrical

connection

box.

Note: Power should be run to a

weather proof disconnect box usually

within 3 feet of the unit.

ELECTRICAL WIRING

6. From the disconnect box

feed the high

Volt wires through a weather proof con-

duit and

run the power through the 7/8"

hole (from knock-out) in the unit’s electri-

cal box. Anchor with a strain relief fitting.

Refer to the wiring diagram.

7. Following the wiring diagram,

run wires

to the High Volt pigtail in the control box

and attach L1 and L2 connections. Also

run green wire to ground lug.

T2HA INSTALLATION INSTRUCTIONS

8. Check wiring diagram for the required

number of low voltage wires to be run

between indoor and outdoor sections.

!

!

9. Connect the 24 Volt wiring matching

color to terminal block designation for

each zone as labeled. Refer to the wir-

ing diagram on the inside front panel

of the condenser, and also refer to the

wiring diagram on the indoor unit. Low

Volt interconnect should be at least 18

AWG.

CAUTION

Make sure that Low Volt wiring for

each circuit is connected to the match-

ing Low Volt wiring.

10. Replace the unit’s electric box cover and

the front panel and tighten screws

.

High Volt

Low Volt

Knock-out