LEK-IG1 Board

Select MCU detect function for power ignition behavior

(SW1):

The functions of the above jumpers are further explained

here.

Power Good Detection

1.

: A power-good signal

from the main board will be sent to the ignition

controller so that the ignition controller can

decide or alter the power state upon the following

instances. (Refer to the flow chart in Chapter 4):
Power-on instance

Power-good signal turned-low instance

Low Voltage Detection

2.

: Turn on this switch to

enable the automatic detection of low voltage

state of the battery. It will automatically turn

off the system when low voltage state has been

detected (Note: the low-voltage condition needs

to remain 30 seconds continually). The voltage

level can be set in the Ignition System Manager

(ISM) which is provided by Lanner as sample code

for functions on the power ignition module. The

default setting of this function: Shutdown

Voltage in the ISM is disabled. (Refer to the flow

chart in Chapter 4 and the Using the Ignition

System Manager (ISM) in Appendix A.)
Watchdog:

3.

Enable this switch to enable shutdown

after watchdog timer count-down to zero. This is a

programmable function. If there is no program to

control and monitor the watchdog timer, set this

jumper to disabled to avoid abnormal shutdown.

The default time-out value is 300 sec( you will need

an AT command to reset watchdog timer; contact

Lanner rep for this program).

ON

SW1

1

2

3

4

8

7

6

5

Selector No.

SW1

Ignition Function

1

Power Good Detection

ON: Enable

OFF: Disable

2

Low Voltage Detection

3

Watchdog

4

Programming MCU

Reserved

The default value is ON for selector 1, ON for se-
lector 2, OFF for selector 3, and OFF for selector 4

MCU (Microcontroller) Function Selection (SW1, SW2):

It is for selecting the microcontroller’s function.

An external RS-232 connector for MCU programming

(CN1)

IGN_CON1

Ignition Control Connector (IGNITION1)

ON

1

2

3

4

SW1

SW2

ON

1

2

3

4

ON

1

2

3

4

Download Data

Normal (Default)

ON

1

2

3

4

ON

1

2

3

4

ON

1

2

3

4

Jumper

Pin No.

Pin NO.

SW1

1-ON, 2-ON, 3-OFF, 4-ON

1-ON, 2-ON, 3-OFF, 4-OFF

SW2

1-OFF, 2-OFF, 3-ON, 4-ON

1-ON, 2-ON, 3-OFF, 4-OFF

Function

Download Data

Normal (Default)

Pin No.

Pin Name

1

REMOTE_POWER_ON

2

3G_POWER_ON

3

IGN_DI0

4

IGN_DI1

4
3
2
1

Pin No.

Pin Name

1

EXT_TXD_R

2

GND

3

EXT_RXD_R

1
2
3

Pin No.

Pin Name

Pin No.

Pin Name

1

IGNITION

6

D2D_EN

2

SYS_POWER_

SWITCH

7

SYS_POWER_OK

3

COM_SOUT

8

GND

4

COM_SIN

9

DC_VIN

5

D2D_PWROK

10

DCIN_VCC

10 9 8 7 1