KACO blueplanet 6400xi User Manual
Page 21

Page 22
blueplanet Operating and Installation Instructions 6400xi - 7600xi
Inverter – Mechanical and technical data
Model
6400xi
7600xi
Visual displays
LEDs: PV generator (green)
Grid-feed (green)
Fault (red)
LCD (2 x 16 characters)
LEDs: PV generator (green)
Grid-feed (green)
Fault (red)
LCD (2 x 16 characters)
Controls
2 keys for display operation and confi guration of parameters
DC cut-off point
Pre-installed and separable DC rotary disconnect switch
Connections
Screw compression terminals in the connection box
Cable connection via conduit fi ttings using 3/4” or 1/2” knockouts on
connection box Terminals accept AWG 4 to AWG 12, 75’C, copper
wire. Torque to 20lb-in (2.2N-m).
Interfaces
RS485, S0, error transmitting relay
Ambient temperature
–4 °F ... +140 °F (> 104 °F power derating)
Internal Temperature monitoring
> 167 °F temperature-dependent power limiting
> 185 °F disconnection from the grid
Max. humidity
95 % (not-condensing)
Cooling
Free convection (fan assist)
Protection class
NEMA-3R
Noise emission
<45 dB (fan operation)
Housing
Aluminium wall-mounted housing
Dimensions W x D x H
44
3/8
x 14 x 8
6/8
in.
44
3/8
x 14 x 8
6/8
in.
Weight
108 lbs
108 lbs
S e c t i o n 3 ·