beautypg.com

Jordan Valve Mark 128PQC Series Control Valve User Manual

Page 3

background image

M

ark

128PQC S

erieS

C

ontrol

V

alVe

-3-

Replacing Packing and Trim continued,

3.

Accessible areas should be cleaned at this

stage, and all necessary maintenance perf-

ormed. The actuator and attached trim parts

can be turned over and held by the valve body.

4.

To separate trim and access packing parts or

seal O-rings, first loosen and remove the valve

plug (Key 25) and remove the packing box

washer (Key 27).

5.

Remove the packing box (Key 28), O-ring

retainer (Key 18), stem O-ring (Key 19) and

diaphragm casing O-ring (Key 31) off the stem.

6.

Install replacement parts as necessary.

6.1.

If a complete packing and trim assem-

bly is being installed, remove the as-

sembly from the tube (Key 37), keepi-

ng the web sleeve (Key 39) on the

assembly so the parts remain in place.

Roll the sleeve back as necessary dur-

ing

installation.

6.2.

Continue pushing the assembly onto

the stem until the valve plug and cage

are pushed away from the packing box

washer or wiper ring. Roll the web

sleeve back into place just past the

packing

box.

6.3.

If installing nitrile/cotton packing, the

packing rings may be lubricated with

silicon based product.

7.

Slide the packing box onto the stem until the

packing box, the O-ring (Key 19) and the O-

ring retainer (Key 18) and the diaphragm casi-

ng O-ring (Key 31) are sealed against the dia-

phragm casing.

7.1.

Ensuring proper positioning of the O-

rings will prevent them from being cut

when other parts are compressed

against

them.

7.2.

Advance the packing spring washer

(Key 29) , packing spring (Key 21),

second packing spring washer, wiper

ring and packing box washer

(Key 27, if included in the assembly)

down onto the stem.

8.

For installation of the packing and trim as

sembly, it is necessary to remove the sleeve,

cage puller (Key 40) and cage (Key 23) from

the valve plug depending on individual valve

configuration.

9.

Fix the valve plug onto the stem, rotating the

plug until the shoulder makes snug contact

with the stem. No further tightening is neces-

sary.

10.

To replace the cage or access the cage O-ring

(Key 22), remove the cage from the body (Key

26) using the cage puller or a wire hook. Re-

placement parts can be installed as necessary.

11.

Attach the actuator and trim to the valve body

(Key 26), paying special attention to the cage

O-ring to prevent damage. Thread the four

nuts (Key 32) to the lower diaphragm casing

assembly screws. Nuts must be tightened to

15-foot-pounds (20N•m).

12.

Reconnect the input signal tubing to the actua-

tor connection of the appropriate diaphragm

casing.

Figure 2: Replacement Packing and Trim
Assemblies for Metal Seated Constructions

37

19

30

28

21

38

25

23

40

22

27

29

39

20

31

18