Beeper
Controls the audible signal for error messages such as media out
warning. This sound can be changed. Default “Off”.
Settings:
Off
(turn beeper off on errors)
Solid
(beeper on continuous until error cleared)
Fast P
(beeper will pulse at a fast rate)
1 Min P
(beeper will pulse every minute)
3 Sec P
(beeper will pulse every 3 seconds)
5 Times
(beeper will pulse 5 times then turn off)
NOTE:
Error condition must be cleared in order to continue plotting.
Offl Err
When set to “Yes”, with an error condition the plotter interface will go offline
to the host. Default “Yes”.
Settings: Yes
or
No
Busy Offl
When set to “Yes”, the plotter interface will assert the busy line to
the host when the plotter goes offline. Default “No”.
Settings:
Yes or No