beautypg.com

Specification, Common electrical specifications, Supplementary intrinsically safe specifications – Ion Science MiniPID User Manual

Page 18

background image

MINIPID 3PIN MANUAL

Ion Science Ltd

Page 18 of 27

Unrivalled Detection. www.ionscience.com

Specification

Common Electrical Specifications:
Supply Voltage on pin 1 Ref to 0 V on pin 3

MiniPID STD supply

V

S

3.3 V+ 0.3 V / - 0.2 V stable (noise free).

Current drawn (at V

S

= 3.3 V, 20

o

C) I

S

24 mA to 33 mA at V

S

= 3.3V,

Power consumption (at V

S

= 3.3 V)

P

110mW (typical)

Peak current at power-up

I

M

120 mA for 0.3 s maximum.


MiniPID Reg.
supply

V

S

3.6 V to 18 V (Non-IS) (variable) maximum.

Current drawn

I

S

30 mA

3 mA (independent to V

S

)

Current Construction Drift

I

ΔT

1.5mA/10°C typical


Voltage on Signal Output pin 2 Ref to 0 V on pin 3

Linear signal output:

V

SO

> 50 mV to Positive Supply Voltage (less

0.1V)
Stepped error states:

V

EO

< 40 mV

Output capacitance:

C

O

1.0 uF through 4k7

+ 0.11 uF at pin

Output resistance:

R

O

6k3

Output clamp:

V

OC

5V1 zener protected by 4k7

resistor.

Supplementary Intrinsically Safe Specifications:

Approval

ATEX Approved Baseefa 07ATEX0060U

Intertek

Class 1 Div 1 Groups A, B, C, D T4

IECEx Approved BAS07.0030U

Conforms to UL standard 913

II 1G Ex ia IIC T4

Certified to CSA standard C22. 2 No. 157

Temperature range

-40

C ≤ Ta ≤55

C (note: Pi where Ta may be taken to 65°c)


Supply Voltage on pin 1 Ref to 0 V on pin 3

MiniPID Standard (with solder blob)
Voltage (Max)

Ui

5.0 V

Current continuous (Max)

Ii

220 mA

Power (Max)

Pi

1.1 W @ +55 °C, 1.0 W @ 60

C; 0.9 W @ 65

C;

Current surge (Max)

Surge < 3.3 A

Capacitance (Max)

Ci

7.0 uF

Inductance (Max)

Li

0 uH

MiniPID Regulated (without solder blob)

Voltage (Max)

Ui

10.0 V

Current continuous (Max)

Ii

220 mA

Power (Max)

Pi

1.1 W @ +55 °C, 1.0 W @ 60

C; 0.9 W @ 65

C;

Current surge (Max)

Surge < 3.3 A

Capacitance (Max)

Ci

1.1 uF

Inductance (Max)

Li

0 uH

Voltage on Signal Output pin 2 Ref to 0 V on pin 3

(line addition)

Voltage (Max)

Ui

10.0 V

Current continuous (Max)

Ii

10 mA

Power (Max)

Pi

50 mW

Capacitance (Max)

Ci

0.12 uF

Inductance (Max)

Li

0 uH

Note: “Signal Output pin 3” Ci to be summed with “Supply Voltage pin 1” Ci above (not countable fault)
Schedule of Limitations
The component must be mounted within apparatus which provides ingress protection of at least IP20,
protection against impact, and protection against possible electrostatic charging of the plastic enclosure.
Warning:
The MiniPID sensor is an Intrinsically Safe device that contains limited energy storing components. An
appropriate Intrinsically Safe interface must be employed for use in hazardous locations noting power
limitations and temperature ranges, and must be installed in strict accordance with applicable safety codes
and guidance given in the Manual. Failure to observe this warning can result in serious injury and/or
property damage.
Version May 2010