4. Inputs
Inputs for Y_StoreParameters, Y_WriteParameters, and Y_AbsoluteEncoderReset
Variable
Name
Data Type
Default Value
Function
bExecute BOOL False
Upon the rising edge, all other function block
inputs are read and the function is initiated.
To modify an input, change the value and
re-trigger the execute input.
sNetId T_AmsNetId
string> A string containing the AMS network identifier nSlaveAddr UINT 0 Fixed address of the EtherCAT slave to which sFile T_MaxString ‘C:\YaskawaPrm.dat’ Contains the path and filename for the file to
of the EtherCAT master device to which the
ADS commands within this Function Block are
directed. See notes for usage.
the commands within this function block
should be sent. See notes for usage.
be created (Y_StoreParameters) or read
(Y_WriteParameters) on the local machine.
Note: Network paths cannot be used.
Note: For Y_StoreParameters, if the file
exists, it will be overwritten.