beautypg.com

Errorid’s – Yaskawa Sigma-5 with CANopen over EtherCAT User Manual

Page 11

background image

Product: TwinCAT, Sigma-5 with CANopen over EtherCAT option

Doc#: TM.SGDV.01

Title: Sigma-5 EtherCAT Function Blocks for TwinCAT

 

Doc#: TM.SGDV.01

Yaskawa America, Inc. Drives & Motion Division

©2011

January 6, 2011

Page 11 of

22

7. ErrorID’s

ErrorID

Description

Details

0-4099
5000+

[TwinCAT-specific]

See the Beckhoff Information System, section “ADS Return
Codes” for details.

4100

Vendor ID mismatch

Product not compatible. This FB is only for Vendor ID
0x00000539 (Yaskawa).

4101

Product Code mismatch

Product not compatible. This FB is only for Product codes
0x02200001 (Sigma-5 Rotary) and 0x02200002 (Sigma-5
Linear). If using Sigma-5 CoE Drive, get latest FB from
Yaskawa.com.

4102 Version

mismatch

Product not compatible. This FB is only for certain EtherCAT
revisions. If using Sigma-5 CoE Drive, get latest FB from
Yaskawa.com, or, see Section 9, “Modifying Function Blocks.”

4103

Object not found

Error reading object data type or data type not supported.

4104

File corrupt

File is corrupt. Store the parameters again.

4105

File ID is 0

No version of the ID of file was read. Possibly incorrect file, or
FB has an error.

4106

File ID mismatch

This file was made with a different version than this Function
Block. Obtain the latest FB from Yaskawa.com

4107

Incorrect FSA state

Not in FSA state "Switch On Disabled". StatusWord expected
as x1xx_0000 (bin). See following notes.

4108

Incorrect Device state

Drive not set to PRE-OP mode. Set the drive to PRE-OP mode
before using this FB. See following notes.

4109

File exists already

When trying to store parameters to a file, that file currently
exists. A new file name or location must be provided.

4110

Servo state incorrect

Servo must be off. StatusWord cannot be x00x_0111,
xx1x_x011_0111, or x0xx_1111 (bin).

4111

Adjusting Status
incorrect

Adjusting status must be 1, 2, 3, or 255, but read as a different
value.

4112

Internal Function Block
Error

Function block internal programming error - Function Block State
Not Found.

4113

Adjusting & Abort
commands failed

Adjusting command failed, so Abort (Step 4) was performed.
But Abort also failed (Status of Adjusting = 2).

4114

Adjusting & Abort
commands failed

Adjusting command failed, so Abort (Step 4) was performed.
But Abort also failed (Status of Adjusting = 2). Reply data for
the Adjusting command failure exists in object 0x2710:03.

4115

Send Request 1008
failed

Error occurred (Status of Adjusting = 2) while performing Send
Request 1008 (Step 1). No reply exists.

4116

Send Request 1008
failed

Error occurred (Status of Adjusting = 3) while performing Send
Request 1008 (Step 1). Reply exists in object 0x2710:03.

4117

Send Preparation failed

Error occurred (Status of Adjusting = 2) while performing Send
Preparation (Step 2). No reply exists.

4118

Send Preparation failed

Error occurred (Status of Adjusting = 3) while performing Send
Preparation (Step 2). Reply exists in object 0x2710:03.