5 Installation Procedure

YASKAWA ELECTRIC TOBP C730600 23C 1000-Series Option SI-P3/V, SI-P3/T Installation Manual

25

Cable Length

Communication speed determines maximum permissible cable length.

Table 7

shows the

specifications for Type A bus cables.

Table 7 Cable Length

GSD Files

For easy network implementation of drives equipped with a PROFIBUS-DP Option, a GSD

file can be obtained from:
U.S.: http://www.yaskawa.com
Europe: http://www.yaskawa.eu.com
Japan: http://www.e-mechatronics.com
Other areas: Contact a Yaskawa representative.

Communication

speed (kbps)

Distance per segment (m)

Communication

speed (kbps)

Distance per segment (m)

9.6

1200 500

400

19.2

1200

1500

200

45.45

1200

3000

100

93.75

1200

6000

100

187.5

1000

12000

100