MP920 QRG Rev1.5
Reference Units (User Units)
FP7: Rated Speed [RPM]
(Default 3000)
OLC022: Speed Reference (when
OBC001D=0
) [10^
n
RU
/min] (Default 3000)
OLC015: Speed Reference (when OBC001D=1) [0.01% of Rated Speed (FP7)] (Default 0)
OLC012: Position Reference [
RU
]
OBC001E: Incremental / Absolute
or
OLC028: Step Distance [
RU
]
OBC0212: Step Direction
OWC00C: Acceleration [ms to Rated Speed (FP7)]
(Default 0)
Servopack Pn80B: Acceleration Rate
[10,000
RU
/sec^2]
(Default 65535)
OWC00D: Deceleration [ms to Rated Speed (FP7)]
(Default 0)
Servopack Pn80E: Deceleration Rate
[10,000
RU
/sec^2]
(Default 65535)
OWC00C=0 & OWC00D =0 sets servopack acceleration/deceleration rate to 65535[10,000 RU/sec^2]
n = 3
when
FP17 bit 4 =0 (RU not used)
n = FP18 when
FP17 bit 4 =1 (RU is used)
KEY
* RU = "reference unit" = "user unit" = "command unit"
* FP = Fixed Parameter
* MCC = Motion Command Code (OWxx20)
* Register Values given for Circuit#1, Axis#/1
*
Bold type
represents default setting
RU
= FP17 bits0-3
0: Pulse (post quad)
1: mm
2: deg
3: inch
If PULSE is not chosen as the RU, use the following
parameters to define the relationship between
PULSE and RU.
FP8: Encoder Pulses (pre-quad) per motor rev
FP21: Motor Revs into gearbox
FP22: Machine Shaft Revs out of gearbox
FP19: RU per Machine Shaft Revolution
Motor
G.B.
8
21
22
19
NOTES:
* Register Addresses assume Circuit#1, Axis#1
* Reference Units not compatible with Function Block programming.
* Default Positioning units are [encoder pulses (post quad)]
* Default Speed Reference units are [1000 pulses/min]
* Default Accel/Decel units are [ms to rated motor rpm]
* MPE720 5.31B "Units" in module configuration do not update
* Motion Module Manual incorrectly lists MCC=11 and Decel (OLC00D) as
not used
Use MCC=11
to change
Deceleration
Use MCC=10
to change
A
cceleration
Use of MCC to change
Servopack Parameters
Applies to SVB ONLY and
NOT SVA
FP17 bit 4 =1 Activates RU Feature
Page 15 of 15