5 installation and uninstallation procedure – Yaskawa 1000 Series Drive Option User Manual
Page 15
5 Installation and Uninstallation Procedure
YASKAWA ELECTRIC TOBP C730600 55D 1000-Series Option PS-A10 Installation Manual
15
■
Dimensions
The option is 163 mm (6.4 in.) tall and adds 50 mm (2.0 in.) to the width of the unit when
installed.
Figure 5
Figure 5 Dimensions
■
UL and CE Compliance
Installation Area
For compliance with UL and CE standards, the option should be placed within the enclosure.
This product must be used in areas with an environment rating no greater than pollution
degree 2 according to UL standards.
Note: 600 V class drives (models CIMR-A5) are not compliant with European
Standards.
External Power Supply
Use a Class 2 power supply as defined by UL standards for the customer-supplied power
supply connection to TB1.
50 mm (2.0 in.)
163 mm (6.4 in.)