3 description of the user interface, Description of the user interface – SMA WINDY BOY User Manual
Page 8

Description of the user interface
SMA Solar Technology AG
8
WBSetup-BEN100411
User Manual
3 Description of the user interface
The following illustration shows the layout of the operating interface of the Windy Boy Setup Tool:
Object
Description
Function
A
Menu bar
The various items can be accessed via the menu
bar.
B
Diagram of the power curve
The power curve of the inverter is displayed in
this diagram.
C
Option field for calculation of the
power curve
Here you can select whether the power curve
should be calculated from nodes or from
coefficients.
D
Option field for presentation of the
power curve
Here you can select whether the power curve is
presented as a curve or as a line.
E
Value range "Nodes"
In this area you can specify the nodes from
which the power curve is calculated.
F
Value range "Parameters"
In this area you can enter the parameters of
your inverter.
G
Button [New]
By using the button you can delete the entered
data.
H
Button [Device selection]
By using this button you can select your inverter
type and take on the factory-installed
parameters.
A
B
C
D
E
F
G
H
I
J