The Sunny Boy 4200TL Multi-String is designed for 230 V grids. The voltage should
be within 198 V and 260 V and the frequency should be within 49.8 Hz and
50.2 Hz. All settings shown below are based on the German standard DIN VDE
0126. You are also able to use other settings.

Limits for AC output

Voltage range

198 V ... 260 V

Frequency range

49.8 Hz ... 50.2 Hz

Voltage range

(without anti-islanding)

180 V ... 260 V

Frequency range

(without anti-islanding)

45.5 Hz ... 54.5 Hz