Installation Manual
7 Settings
7.1 Setting the MODE
The "MODE" rotary switch is set to the position "0" for delivery. Other positions are not permitted and
are intended for SMA Service only.
• If the "MODE" rotary switch is not set to the correct position, turn the arrow of the "MODE"
rotary switch to the correct position using a 2.5 mm screwdriver.
7.2 Setting the NetID
Plants with SMA Bluetooth operating in close proximity to one another are distinguished by their
individual NetID. All devices in a plant must have the same NetID. You can set the
SMA Bluetooth Repeater to the NetID of your plant using the "NetID" rotary switch.
• If the plant NetID is not known, read off the NetID from one of the devices in the plant
(e.g. Sunny WebBox with Bluetooth or inverter with Bluetooth).
• Use a 2.5 mm screwdriver to turn the arrow of the "NetID" rotary switch to the plant NetID.
Assignment of the rotary switch positions
*
*
See section 10.2 for information on the status of the Bluetooth LEDs.
NetID
Function
0
Bluetooth is switched off.
1
(Status upon delivery)
Bluetooth is switched on.
The device can connect to a maximum of 2 communication products. The
device cannot establish a connection to other inverters or
SMA Bluetooth Repeaters.
2 to 9 and A to F
Bluetooth is switched on.
The device can interlink with all SMA Bluetooth products having the same
NetID.
NetID 1 is possible for plants with 1 inverter
You may leave the default NetID set to 1 in your inverter if your Bluetooth plant consists of the
following products:
• Maximum 1 inverter
• Maximum 1 computer with Bluetooth and the Sunny Explorer software
• Maximum 1 Sunny Beam of the type BEAM-BT-11.GR1
or
• Maximum 1 inverter
• Maximum 2 Sunny Beams of the type BEAM-BT-11.GR1
In all other cases you must determine a free NetID (see Sunny Explorer Help).