beautypg.com

10 technical data, 1 meteo station, Technical data – SMA METEO STATION Installation User Manual

Page 29: Meteo station

background image

SMA America, LLC

10  Technical Data

Installation Manual

MeteoStation-eng-IA-IUS122210

29

10 Technical Data

10.1 Meteo Station

General Data

Mechanical Data

Voltage Supply

Ambient Conditions

Communication

Certified countries

USA/Canada

Recommended installation location

Outdoors

Diameter x height

6 in. x 10

1

2

in. (150 mm x 268 mm)

Weight with bracket, without connection cable

3 lbs. (1.3 kg)

Mounting type

Pole fixtures: Ø 2

3

8

in. to 3 in.

(60 mm to 76 mm)

Voltage supply

Power supply unit

Supply voltage

24 V DC ± 20%

Typical current input

135 mA

Maximum current consumption

500 mA

Typical power consumption

< 2 W

Degree of protection

NEMA 3

Ambient temperature

− 40°F to 140°F ( − 40°C to +60°C)

Relative humidity

5% to 95 %

Max. permissible height above MSL

9,840 ft. (3,000 m)

Communication

RS485