5  Mounting

Installation Manual

MeteoStation-eng-IA-IUS122210

17

5 Mounting

5.1 Mounting the Connecting Terminal Plate and the

Power Supply Unit

Requirements:

☐ Adhere to the requirements in the attached installation instructions from Phoenix Contact.
☐ The mounting location must be indoors.
☐ A maximum cable route of 33 ft. (10 m) to the PV modules must be taken into account.
☐ A maximum RS485 communication bus length of 328 ft. (100 m) must be taken into account.
☐ The power supply unit must be protected from dust, moisture and aggressive substances.

1. Mount the power supply unit and connect it to the connecting terminal plate (see Installation

Instructions for Power Supply Unit from Phoenix Contact).

2. Mount the connecting terminal plate on the top-hat

rail.

5.2 Mounting the Meteo Station

Requirements:

☐ The ambient temperature must be between ‒40°F to +140°F ( − 40°C to +60°C).
☐ The diameter of the pole on which the Meteo Station is mounted must be between 2

3

8

in. and

3 in. (60 mm to 76 mm).

☐ The pole must be stabilized by an appropriate wall or floor fixture.
☐ The mounting location must be shadow-free and with an unimpeded panoramic view at the

height of the pyranometer.

☐ Remember that the maximum cable length to the connecting terminal plate is 33 ft. (10 m).
☐ The Meteo Station must be protected from aggressive or toxic substances.